BR Sales being one of the leading service providers in industry we are engaged in providing high quality Industrial Project Consultancy services. Our experts interact with the clients and analyze their needs and offer services accordingly. We are offering Consultancy for Electronic Products and Ceramic Lined Equipment’s.
Singled phased motors are widely used in home applications. they are operated directly by switch. MCB of mechanical starters which does not provide sufficient protection to motors and does not isolate the application in case of power failure Electronics single phase motor starters provide protection to motor against over current, high voltage and isolates the motor in case of power failure.
Starters are available in elegent, dust proof ABS Plastic enclosure with different colours like white gray, ivory and wipro gray.
Operating voltage | 140 to 285 V |
Current range | 2-5 Amp, 4-10 Amp, 8-14 Amp, 10-16 Amp, 14-22 Amp |
Overload tripping | As per inverse time current characteristic. |
High voltage cut-off | 285 V |
Cut-in | 270 V |
On-off/reset | By manual push button |
Indications | Green - motor on red – overload |
For conventional single phase motors like Grinders, Polishers,Geysers,Wood working machines etc. provides overload and high voltage cut-off for any applience.
For Compressors/Air conditioners/Water coolers. Exhaust fans in factories and theaters.provides three minuits time delay in auto restart and auto/manual facility.
For unattended pumps. Build in dry-run protection with 30% to 70% adjustable dry-run current.
Features | Switch | MCB | Mechanical Starters | GELCO Starter |
---|---|---|---|---|
Overload Protection | Not provided | Limited tips in short circuits only. | Provided but not accurate | Accurate overload protection |
High Voltage Cut-Off | Not provided | Not provided | Not provided | Provided at 285-290V |
On-Off Operation | Manual by switch | Manual by switch | Manual by push buttons | Manual by push buttons |
Power Failure Condition | Remains On | Remains On | Remains On | Isolates the motor when power fails |
Life And Maintenance | Short life & not repairable | not repairable | not repairable | Long life and repairable |
With 20 years experience in motor protection, It developed a new 3 phase Direcr On Line Starter with following features.
System Voltage: | 415 V, 3Ø, 50 Hz ± 15% |
Current Range: | Type: 303 - 1 - 2.5 Amp 304 - 2 to 5 Amp 305 - 4 to 10 Amp 306 - 8 to 20 Amp |
Overload Tripping | As per inverse time current characteristic |
Low tripping voltage | Below 260V within 4 to7 Sec. |
High Voltage Tripping | Above 480V within 4 to 7 Sec. |
Single Phasing Tripping | Upto motor terminal within 4 to 7 Sec. |
*Low/High voltage cut-off can be given as per party's requirement on request.
DOL Starter for any three phase motor upto 7.5 HP. Inbuilt Low/High voltage cut off, single phasing upto motor terminal and electronic overload protection is provided. Adaptor facility is not provided.
DOL Starter for any three phase motor upto 7.5 HP. Inbuilt Low/High voltage cut off, single phasing upto motor terminal and electronic overload protection is provided. Adaptor facility is provided.
DOL Starter for any three phase motor upto 7.5 HP. Inbuilt Low/High voltage cut off, single phasing upto motor terminal and electronic overload protection is provided. Additional facility of autoswitch with Auto/Manual switch. In auto mode starter will start automatically after 1 min. if healthy input supply is available.
DOL Starter for any three phase motor. upto 7.5 HP designed for exhaust fan application. Inbuilt Low/High voltage cut off, single phasing upto motor terminal and electronic overload protection is provided. Additional facility for duty cycle timer is provided. Once starter is switched on by pushbutton, it automatically switch ON and OFF motor depending on duty cycle timing. Manual switch is not provided.