BR Sales being one of the leading service providers in industry we are engaged in providing high quality Industrial Project Consultancy services. Our experts interact with the clients and analyze their needs and offer services accordingly. We are offering Consultancy for Electronic Products and Ceramic Lined Equipment’s.
Panel meters are applicable to measure various power parameters like voltage, current, frequency. This has vide application area like control panels, testing instrument, machinery, etc. It is also developed a hour meter to make a complete range of panel meters.
It was recently developed a new range of micro controller based panel meters. It range of Panel meters has been developed with latest micro controller based technology to enhance accuracy level and functionality. Some meters are also contrived with multiple user friendly parameters such as MM-9601. During development of this range certain key parameters like compact size, user friendly programming has been taken care.
Supply | 230V AC ± 20%, 50 Hz |
Display Parameter | Voltage |
Range | 0 - 750 V (AC) |
Display | 0.56" Seven Segment LTD |
Dimension | VI-48 / AI-48 VI-96 / AI-96 |
Size(mm) | 48 x96 96x96 |
Cut Out(mm) | 44x92 92x92 |
Depth(mm) | 78 65 |
Weight(Gms) Approx. | 320 500 |
Selection Method | - |
Reset | - |
Operating Temperature | 0oC to 50oC |
Supply | 230V AC ± 20%, 50 Hz |
Display Parameter | Ampere |
Range | 0 - 20 A (AC) |
Display | 0.56" Seven Segment LTD |
Dimension | - |
Size(mm) | - |
Cut Out(mm) | - |
Depth(mm) | - |
Weight(Gms) Approx. | - |
Selection Method | - |
Reset | - |
Operating Temperature | 0oC to 50oC |
Supply | 230V AC ± 20%, 50 Hz |
Display Parameter | Frequency |
Range | 0-50.0 Hz |
Display | 0.56" Seven Segment LTD |
Dimension | FI-96 |
Size(mm) | 96x96 |
Cut Out(mm) | 92x92 |
Depth(mm) | 65 |
Weight(Gms) Approx. | 265 |
Selection Method | - |
Reset | - |
Operating Temperature | 0oC to 50oC |
Supply | 230V AC ± 20%, 50 Hz |
Display Parameter | Voltage & Ampere |
Range | 0-20A & 0 - 550V (AC) |
Display | 0.56" Seven Segment LED |
Dimension | AVI-48 AVI-96 |
Size(mm) | 48x96 96x96 |
Cut Out(mm) | 44x92 92x92 |
Depth(mm) | 78 65 |
Weight(Gms) Approx. | 320 500 |
Selection Method | By Slide Switch on front |
Reset | - |
Operating Temperature | 0oC to 50oC |
Supply | 230V AC ± 20%, 50 Hz |
Display Parameter | Voltage & Ampere |
Range | 0-700A & 0-550V External CT required Beyond 5Amp. |
Display | 0.56" Seven Segment LED |
Dimension | AVM-96 |
Size(mm) | 96x96 |
Cut Out(mm) | 92x92 |
Depth(mm) | 65 |
Weight(Gms) Approx. | 440 |
Selection Method | By Slide Switch on front |
Reset | - |
Operating Temperature | 0oC to 50oC |
Supply | 110/230/415V AC, 50Hz |
Display Parameter | Time (Hour) |
Range | 0-99999.9 Hour |
Display | 0.4" Seven Segment LTD |
Dimension | DHM-5701 |
Size(mm) | 38x63 |
Cut Out(mm) | 29x53 |
Depth(mm) | 85 |
Weight(Gms) Approx. | 95gm |
Selection Method | - |
Reset | Manual |
Operating Temperature | 0oC to 50oC |
Supply | 230 +/- 20 % Vac (Aux.) |
Display Parameter | Kwh |
Range | 0-9999 kWh |
Display | 0.4" seven segment display |
Size(mm) | 96x96 |
Cut Out(mm) | 92x92 |
Depth(mm) | 110 |
Weight(Gms) Approx. | - |
Selection Method | Programming of CT ratio through key pad on front (External CT Requires) |
Indication | NA |
Reset | By Pressing UP key for few seconds |
Operating Temperature | 0º Degree to 65º Degree |
Supply | 230 +/- 20 % Vac (Aux.) |
Display Parameter | Volt(P-N),Volt (P-P), Current, Frequency |
Range | Volt- 20-300 VAC ( P-N) Current - 0-999 Amp. Frequency 0-60 Hz |
Display | 3 set of 0.4" seven segment display for voltage,current, frequency resp. |
Size(mm) | 96x96 |
Cut Out(mm) | 92x92 |
Depth(mm) | 110 |
Weight(Gms) Approx. | - |
Selection Method | Programming through Key Pad. Programming parameters are CT ratio, selection of Voltage (P-N) or (P-P) and Phase current |
Indication | VRY, VYB, VBR, VRN, VBN, VYN ,IR, IY, IB |
Reset | NA |
Operating Temperature | 0º Degree to 65º Degree |
Supply | 230 +/- 20 % Vac |
Display Parameter | voltage |
Range | 100- 500 V AC |
Display | 0.56" seven segment display |
Size(mm) | 38x63 |
Cut Out(mm) | 29x53 |
Depth(mm) | 85 |
Weight(Gms) Approx. | - |
Selection Method | NA |
Indication | NA |
Reset | NA |
Operating Temperature | 0º Degree to 65º Degree |
Supply | 230 +/- 20 % Vac |
Display Parameter | Current |
Range | 0-20 Amp. (Without
CT.) 0-50,0-100 amp. (with Use of external CT) |
Display | 0.56" Seven segment display |
Size(mm) | 38x63 |
Cut Out(mm) | 29x53 |
Depth(mm) | 85 |
Weight(Gms) Approx. | - |
Selection Method | NA |
Indication | NA |
Reset | NA |
Operating Temperature | 0º Degree to 65º Degree |
Supply | 230 +/- 20 % Vac (Aux.), 50-60 Hz |
Display Parameter | Voltage, Current, Frequency, Power(kW), Active Power (kVa), Reactive Power(kVar), Energy (kwh),Power factor, |
Range | Voltage:20-300Vac (P-N),0-500Vac(P-P), Current: 0-999.9 Amp, Power(kW): 0-999.9, Active Power(kVa): 0-999.9, Reactive Power (kVar) : 0-999.9, Energy : 0-9999, Frequency : 0-60 Hz, Power Factor - 0 to 1. All parameter for individual phase and system can be display. |
Display | 4 set of 0.4 " seven segment display |
Size(mm) | 96x96 |
Cut Out(mm) | 92x92 |
Depth(mm) | 110 |
Weight(Gms) Approx. | - |
Selection Method | By Programming Key pads. external CT is Require. CT ratio can be programmed by programming key pad |
Indication | Indications for all above parameters for individual phase and system. |
Reset | Reset kwh By Pressing SYSTEM key for few seconds (kwh) |
Operating Temperature | 0º Degree to 65º Degree |
Supply | 230 +/- 20 % Vac (Aux.) |
Display Parameter | Voltage, Current, Frequency, Power(kW), Active Power (kVa), Reactive Power(kVar), Energy (kwh),Power factor, Crest factor, Frequency(Hz) |
Range | Voltage:20-300Vac (P-N), Current: 0-999.9 Amp, Power(kW): 0-999.9 ,Active Power(kVa): 0-999.9, Reactive Power(kVar) : 0-999.9, Energy : 0-9999, Frequency : 0-60 Hz, Power Factor - 0 to 1. |
Display | 4 set of 0.56 " seven segment display |
Size(mm) | 96x96 |
Cut Out(mm) | 92x92 |
Depth(mm) | 110 |
Weight(Gms) Approx. | - |
Selection Method | By Programming Key pads. external CT is Require. CT ratio can be programmed by programming key pad |
Indication | Indications for all above parameters for individual phase |
Reset | Reset By Pressing SYSTEM key for few seconds |
Operating Temperature | 0º Degree to 65º Degree |